{"trade":"hvac","month":"2026-01","monthStart":"2026-01-01","monthEnd":"2026-01-31","fetchedAt":"2026-07-31T10:16:56.465Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"total":42,"totalReportedCost":9573326,"costedCount":42,"largestReportedCost":1436936,"truncated":false,"permits":[{"permit":"101078117","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-07","address":"3348 W 87TH ST","workDescription":"SELF-CERT 2019 CBC, ALTERATION OF EXISTING GROUND FLOOR OAK STREET HEALTH TENANT SPACE TO EXPAND INTO ADJACENT VACANT MERCANTILE TENANT SPACE. EXPANSION SPACE IS CURRENTLY A VACANT CLOTHING STORE. INTERIOR ALTERATION WITH MODIFICATION OF EXISTING STOREFRONT, PLUMBING, ELECTRICAL AND HVAC. OCCUPANCY WILL BE TYPE B, CONSTRUCTION TYPE IIIB.","reportedCost":1436936,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101078117"},{"permit":"B200455771","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-22","address":"157 W GRAND AVE","workDescription":"HYDRONIC PIPING EXTENSION/RECONFIGURATION, REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   2 COOLING TOWER(MARLEY M#NC8401KAN ROOF)  1 COOLING TOWER(MARLEY, M#AQ494H1QAF, ROOF)  1 CHILLER(WATER FURNACE,M#T3HS050SN23AADD1N6GCSSNSSS, P1 MECHANICAL ROOM) . ELECTRICAL WORK UNDER THIS PERMIT = YES . LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK,  EXTERIOR ROOF AND P1 MECHANICAL ROOM.","reportedCost":1070880,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200455771"},{"permit":"101076603","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-02","address":"2335 S WENTWORTH AVE","workDescription":"SELF-CERT 2019 CBC, ALTERATION OF EXISTING SECOND FLOOR OAK STREET HEALTH TENANT SPACE TO EXPAND INTO ADJACENT TENANT SPACE. EXPANSION SPACE IS CURRENTLY A HOTEL CONFERENCE ROOM. INTERIOR ALTERATION WITH MODIFICATION OF EXISTING STOREFRONT, PLUMBING, ELECTRICAL AND HVAC. OCCUPANCY WILL BE TYPE B, CONSTRUCTION TYPE IIIB.","reportedCost":844895,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076603"},{"permit":"101074367","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2026-01-14","address":"3142 S WELLS ST","workDescription":"ERECT A NEW 3 STORY WITH BASEMENT MASONRY 3 DWELLING UNITS MULTI-UNIT RESIDENTIAL BUILDING INCLUDING ARCHITECTURAL, ELECTRICAL, HVAC, PLUMBING WORK AND A 3-STORY OPEN REAR EGRESS STAIR AS PER PLANS.  CONSTRUCT A CONCRETE PAD AT REAR TO ESTABLISH THREE (3) UNENCLOSED ACCESSORY OFF-STREET PARKING STALLS ACCESSED BY A PUBLIC ALLEY AND THREE (3) UNENCLOSED ON-SITE BICYCLE PARKING SPACES AS PER PLANS.","reportedCost":800000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074367"},{"permit":"101073154","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-07","address":"3843 N HERMITAGE AVE","workDescription":"RENOVATION OF AN EXISTING 2 STORY SINGLE FAMILY RESIDENCE WITH BASEMENT. UPDATED HVAC. ATTIC ADDITION.REMOVAL OF REAR ENCLOSED PORCH. NEW FIRST AND SECOND STORY NORTH SIDE ADDITION AND NEW REAR STAIR.","reportedCost":800000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073154"},{"permit":"101077350","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-16","address":"932 N MOZART ST","workDescription":"SELF-CERT 2019 CBRC: INTERIOR ALTERATION OF AN EXISTING 4-STORY FOUR UNIT BRICK APARTMENT BUILDING INCLUDING NEW HVAC AND PLUMBING SYSTEMS AND ELECTRICAL UPGRADES.  DAMGED FLOOR JOISTS AND SUBFLOORING TO BE REBUILT IN SECOND FLOOR UNIT.  EXISTING WINDOWS TO REMAIN OR BE FILLED.  (OCCUPANCY TYPE: R-2, CONSTRUCTION TYPE III-B)","reportedCost":530000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077350"},{"permit":"101074680","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-07","address":"5353 N BROADWAY","workDescription":"INTERIOR & EXTERIOR REMODELING OF THE EXISTING GROCERT STORE INTO A NEW HOT POT RESTAURANT INCLUDING ARCHITECTURAL , HVAC, ELECTRICAL AND PLUMBING WORK.","reportedCost":500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074680"},{"permit":"101074315","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2026-01-15","address":"5165 S MICHIGAN AVE","workDescription":"SPR 2019 CBC - 5A RESIDENTIAL 3 FLAT (3 DU), SLAB ON GRADE, 3-STORY NEW FRAME CONSTRUCTION GROUND UP, NEW ELECTRICAL, PLUMBING, HVAC, PARKING PAD, FENCE.AS PER PLANS**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":400000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074315"},{"permit":"101068824","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-29","address":"2653 S LAWNDALE AVE","workDescription":"CBC 2019 SPR: INTERIOR RENOVATIONS & REMODELING AT EXISTING FIRST FLOOR GALLERY. REPLACE BATHROOM FIXTURES, COUNTERS, CABINETS & FIXTURES. NEW LIGHTING THROUGHOUT. PLUMBING & ELECTRICAL REPAIRS. FURNACE REPAIR AND DUCKWORK REPLACEMENT. (B3-2 / A3 ASSEMBLY GROUP & R3 (2) APARTMENTS @ 2ND FLOOR)","reportedCost":250000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101068824"},{"permit":"101070765","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2026-01-21","address":"1727 W 106TH ST","workDescription":"NEW SFH, TYPE V-5 NEW CONSTRUCTION. INCLUDING NEW ELECTRICAL, HVAC, AND PLUMBING SYSTEMS THROUGHOUT. NEW TWO-CAR DETACHED GARAGE.","reportedCost":225000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101070765"},{"permit":"101076872","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-20","address":"2618 W RICE ST","workDescription":"SPR 2019 CBRC. INTERIOR ALTERATIONSEXISTING SINGLE FAMILY RESIDENCE. RENOVATIONS TO INCLUDE: NEW INTERIOR ROOM LAYOUT WITH UPDATED KITCHEN AND BATHROOMS,NEW HVAC UNITS,AND PLUMBING MODIFICATIONS TO OCCUPANCY GROUP R-5, 2 - STORY, TYPE 5-A, FRAME AND MASONRY BUILDING.","reportedCost":225000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076872"},{"permit":"101076917","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-13","address":"1953 W SUMMERDALE AVE","workDescription":"SELF CERT PERMIT FOR CONVERTING TWO FLAT INTO SINGLE FAMILY RESIDENCE. 3418 SQUARE FEET OF WORK AREA ON TWO FLOORS AND BASEMENT. NEW REAR ADDITION, DECK AND GARAGE ROOF DECK. NEW ELECTRIC SERVICE PANEL. NEW FURNACES AND AC. NEW WATER SERVICE.","reportedCost":200000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076917"},{"permit":"101077133","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-26","address":"3447 W MELROSE ST","workDescription":"SPR 2019 CBRC: INTERIOR REMODELING TO EXISTING 2-UNIT FRAME RESIDENCE TO INCLUDE WORK IN GROUND FLOOR LEVEL ONLY INCLUDING NEW FRAMING, ELECTRCAL, PLUMBING, HVAC, CONCRETE SLAB, FOUNDATION WORK, AND STEEL BEAM (CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)","reportedCost":175000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077133"},{"permit":"101065053","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-14","address":"5133 S ARCHER AVE","workDescription":"SPR 2019 CBC. EXISTING 2 STORY MIXED-USE BUILDING. WORK ONLY AT 1ST FLOOR. CONVERSION OF EXISTING BAR/TAVERN INTO THE RESTAURANT. INTERIOR RENOVATION INCLUDING ELECTRICAL, HVAC AND PLUMBING. ALL WORK AS PER PLANS.","reportedCost":175000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101065053"},{"permit":"101073822","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-15","address":"2048 N NEWLAND AVE","workDescription":"SPR 2019 CBRC - ADDITION TO EXISTING BUILDING TO HAVE MASTER SUITE WITH EXTRA BEDROOM AND NEW STAIR LOCATION. 1ST FLOOR NEW DRYWALL THRU-OUT WITH NEW WINDOWS AND NEW KITCHEN LAYOUT. NEW FURNACE IN ADDITION. PANEL UPGRADE. MINOR ELECTRICAL WORK IN BASEMENT; IN AN EXISTING 1 STORY SINGLE FAMILY RESIDENCE WITH BASEMENT - (OCCUPANCY GROUP R-5; TYPE IIIA CONSTRUCTION)","reportedCost":170000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073822"},{"permit":"101077144","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-12","address":"1936 N SHEFFIELD AVE","workDescription":"SELF-CERT 2019 CBRC; INTERIOR ALTERATIONS TO AN EXISTING REAR COACH HOUSE'S DUPLEX UNIT. THE 2-STORY MASONRY, TYPE IIIB, GROUP R-5, 2-UNIT BUILDING WITH BASEMENT IS ON THE SAME LOT WITH FRONT 3-STORY, 3-UNIT BUILDING. THE RENOVATION WORK IS LIMITED TO THE COACH HOUSE AS NOTED;- REPLACE EXISTING KITCHEN CABINETS & APPLIANCES & INSTALL RECESSED LIGHTS AT 1ST FLOOR UNIT.- INSTALL NEW PARTITIONS FOR 2 BEDROOMS & 2 BATHROOMS AT UNIT'S BASEMENT LEVEL, WITH REPLACED      CONCRETE FLOOR SLAB WITH PERIMETER DRAIN TILE.- REBUILD DUPLEX UNIT'S INTERIOR STAIRWAY AS EXISTED.- ELECTRICAL, HVAC & PLUMBING MODIFICATIONS PER PLANS.","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077144"},{"permit":"101076691","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-09","address":"6536 S MINERVA AVE","workDescription":"SPR 2019 CBC. NEW SECOND FLOOR REAR FRAME ADDITION TO EXISTING 3-STORY SFR WITH BASEMENT. (OCCUPANCY R-5, CONSTRUCTION TYPE VA). INTERIOR ALTERATIONS INCLUDING ELECTRICAL, PLUMBING, HVAC AND CONVERSION OF 3RD FL. TO UNFINISHED ATTIC SPACE. NEW REAR WOOD DECK. EXT. ALTERATIONS INLCUDE THE REMOVAL OF THE WEST BAY WINDOW ON THE SOUTH ELEVATION & INFILL OF THE EXT. WALL.  REMOVAL OF AS-BUILT FENCING ALONG THE REAR PROPERTY LINE & CONSTRUCT NEW CONCRETE PAD AT REAR FOR TWO UNENCLOSED OFF-STREET PARKING SPACES. ALL WORK AS PER PLANS.(CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076691"},{"permit":"101078016","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-30","address":"1917 W DIVISION ST","workDescription":"SELF-CERT 2019 CBRC; ALTERATIONS TO THE 1ST FLOOR COMMERCIAL TENANT SPACE OF THE 3-STORY, MIXED-USE, TYPE IIIA BUILDING. THE PROJECT IS TO BUILDOUT A CLOTHING STORE, GROUP M, MERCANTILE USE, WITH SALES AREA, BREAKROOM, CHANGE ROOM & TOILET. WORK IS TO INCLUDE NEW PARTITIONS & HVAC SYSTEM, ALONG WITH ELECTRICAL & PLUMBING MODIFICATIONS. ADDITIONALLY, REBUILD LIGHTWELL BASE & NEW METAL PANELS AT THE 1ST FLOOR BUILDING'S FACADE.","reportedCost":145000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101078016"},{"permit":"101076328","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2026-01-08","address":"3340 W CARROLL AVE","workDescription":"DDS / 2019 CBC: REVISION TO PERMIT 101051702 FOR MODIFICATIONS TO THE HVAC SYSTEM TO SEPARATE THE TOILET EXHAUST FROM GENERAL EXHAUST & MODIFICATIONS TO INTERIOR & EXTERIOR FIRE RATED WALLS IN A 3-STORY RESIDENTIAL APARTMENT 'COURTYARD' BUILDING (14 DWELLING UNITS) AS PER PLANS.  (OCCUPANCY GROUP: R-2 / TYPE 5A CONSTRUCTION) CONSULTANT REVIEWER: V3 COMPANIES OF IL","reportedCost":144115,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076328"},{"permit":"101077009","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-21","address":"433 E 46TH PL","workDescription":"SPR 2019 CBRC. INTERIOR ALTERATIONS & REMODELING TO EXISTING TWO STORY BRICK SFR WITH BASEMENT (CONSTRUCTION IIIA, OCCUPANCY R-5). INTERIOR ALTERATIONS INCLUDE ELECTRICAL, PLUMBING AND HVAC. NEW TWO CONCRETE REAR PARKING STALLS. ALL WORK AS PER PLANS.**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":120000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077009"},{"permit":"101075893","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-15","address":"7010 N CLARK ST","workDescription":"SELF-CERT 2019 CBRC: INTERIOR RENOVATION/TENANT BUILDOUT FOR A GROUND FLOOR RETAIL MARKET IN AN EXISTING 1-STORY BUILDING INCLUDING MODIFIED STOREFRONT WINDOWS/ENTRANCE, NEW PLUMBING, NEW ELECTRICAL AND NEW HVAC. NO CHANGE TO DEMISING WALLS OR ROOF. (OCCUPANCY GROUP M; TYPE IIIB CONSTRUCTION)","reportedCost":120000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075893"},{"permit":"101071192","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-09","address":"5659 N ROCKWELL ST","workDescription":"DECOMMISSION EXISTING HEATING SYSTEM AND INSTALL (8) NEW GAS FURNACES WITH A/C UNITS & DUCTWORK IN AN EXISTING R-2 MULTI UNIT RESIDENTIAL BUILDING.  UPGRADE BUILDING ELECTRICAL SERVICE TO A NEW 1 PHASE, 120/240V, 400 AMP SERVICE.","reportedCost":100000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101071192"},{"permit":"101074729","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-05","address":"5014 W CHICAGO AVE","workDescription":"SC 2019 CBRC: INTERIOR ALTERATION TO INCLUDE RENOVATION AND REPAIR TO THE 1ST FLOOR ONLY OF THE PROPERTY. EXTERIOR WORK IS REPLACING EXISTING WINDOWS AND DOORS AND ROOF.  INTERIOR WORK TO INCLUDE DEMOLISHING THE EXISTING WALLS DOWN TO THE WOOD STUDS AND REPLACING THE DRYWALL. THE EXISTING LAYOUT WILL REMAIN. WORK WILL ALSO INCLUDE NEW ELECTRICAL DEVICES (EXISTING SERVICE PER UNIT TO REMAIN) AND NEW HVAC EQUIPMENT AND DISTRIBUTION. THE EXISTING BATHROOMS WILL BE RECONFIGURED TO BE SINGLE USER BATHROOMS. PLUMBING FIXTURES WILL BE REPLACED.(OCCUPANCY GROUP  B; TYPE IIIB CONSTRUCTION)","reportedCost":100000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074729"},{"permit":"101076312","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-22","address":"4152 N MASON AVE","workDescription":"SELF-CERT 2019 CBC: ADDITION TO EXISTING BUILDING FOR NEW 2ND FLOOR ADDITION FOR NEW PRIMARY SUITE WITH BATHROOM AND NEW ELECTRIC HVAC SYSTEM, NEW 200AM ELECTRICAL SERVICE UPGRADE FROOM EXISTING.  2 STORY 23'  TALL SINGLE FAMILY HOME (OCCUPANCY GROUP R-5, TYPE III-B CONSTRUCTION)","reportedCost":97000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076312"},{"permit":"101077626","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-08","address":"5045 W ERIE ST","workDescription":"SELF-CERT 2019; RENOVATE THE EXISTING 2-STORY BRICK, TYPE IIIB WITH 2-RESIDENTIAL UNITS, GROUP R-5 BUILDING WITH BASEMENT. THE WORK IS TO INCLUDE;- RENOVATE 2 OPEN PLAN APARTMENTS WITH 3 BEDROOMS AT FIRST FLOOR & 4 BEDROOMS AT 2ND FLOOR.- NEW BATHROOM & 2 STORAGE ROOMS AT BASEMENT.- NEW HVAC SYSTEMS, UPGRADED ELECTRICAL & PLUMBING MODIFICATIONS PER PLANS.- REBUILD FRONT CONCRETE ENTRY STAIRS AS EXISTED.","reportedCost":80000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077626"},{"permit":"101074442","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-08","address":"7335 S PRAIRIE AVE","workDescription":"SELF CERT CBRC 2019: REHAB TO EXISTING 1 1/2 STORY SINGLE FAMILY MASONRY BUILDING WITH BASEMENT & NEW POWDER ROOM, ELECTRICAL, AND HVAC SYSTEM. (IIIA, R-5)","reportedCost":80000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074442"},{"permit":"101077499","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-12","address":"3308 W DIVERSEY AVE","workDescription":"SELF CERTIFICATION CBC. INTERIOR REMODELING OF THE FIRST-FLOOR UNIT AND BASEMENT, INCLUDING ELECTRICAL, HVAC, AND PLUMBING WORK. THIS WORK IS CONTAINED WITHIN THE EXISTING TWO-STORY, TWO-DWELLING BRICK BUILDING. THERE IS NO WORK PLANNED FOR THE SECOND-FLOOR UNIT. ALL WORK AS PER PLANS.","reportedCost":75000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077499"},{"permit":"101076941","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-21","address":"110 N WACKER DR","workDescription":"SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE TO INCLUDE DEMO, NEW PARTITIONS, DOORS, CEILINGS, ELECTRICAL, PLUMBING AND HVAC AS PER PLANS. NO STRUCTURAL WORK. B-BUSINESS, 1A CONSTRUCTION.","reportedCost":72000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076941"},{"permit":"101076898","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-15","address":"1846 W BYRON ST","workDescription":"SELF-CERT: ERECT NEW 2- STORY REAR FRAME ADDITION WITH BASEMENT, INTERIOR & EXTERIOR REHAB, AS PER ARCHITECT'S PLANS, IN EXISTING 2-STORY WITH BASEMENT SINGLE FAMILY FRAME RESIDENCE. THE SCOPE OF WORK INCLUDES: ARCHITECTURAL, PLUMBING, HVAC, AND ELECTRICAL. CURRENT & PROPOSED USE: SINGLE-FAMILY RESIDENCE","reportedCost":65000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076898"},{"permit":"B200454467","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-08","address":"9311 S VANDERPOEL AVE","workDescription":"SCOPE: NONSTRUCTURAL INTERIOR REPLACEMENT OF DRYWALL, PLUMBING FIXTURES WITH ASSOCIATED PIPING AND ELECTRICAL. NO FLOOR PLAN ALTERATIONS OR HVAC WORK. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1ST FLOOR.","reportedCost":55000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200454467"},{"permit":"101077378","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-16","address":"10833 S ARTESIAN AVE","workDescription":"SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS ONLY TO EXISTING 2 STORY SFR WITH BASEMENT. WORK INCLUDES RECONFIGURATION OF 1ST FLOOR KITCHEN, INSTALLATION OF NEW POWDER ROOM. ALSO INCLUDES CABINETRY, FIXTURES, LIGHTING AND HVAC ADJUSTMENTS IN AREA OF WORK. NO WORK TO EXTERIOR ENVELOPE OR BUILDING HEIGHT. NO OCCUPANCY CHANGE (OCCUPANCY GROUP R-5, TYPE IIIA CONSTRUCTION) ALL WORK PER PLANS.","reportedCost":50000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101077378"},{"permit":"101075098","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-12","address":"6822 S JUSTINE ST","workDescription":"SPR 2019 CBRC: ALTERATIONS TO EXISTING TWO-UNIT RESIDENCE. WORK CALLS FOR THE INSTALLATION OF DRYWALL THROUGHOUT; NEW PLUMBING, ELECTRICAL, AND HVAC FOR BOTH UNITS; THE INSTALLATION OF NEW WINDOWS, NEW BATH AND BEDROOMS IN BASEMENT, AND CONSTRUCTION OF A NEW REAR PORCH. CERTIFIED PLAN CORRECTIONS.","reportedCost":50000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075098"},{"permit":"101063258","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-21","address":"3419 N PAULINA ST","workDescription":"SPR 2019 CBC. REVISION TO PERMIT NUMBER 100901961 TO CHANGE SWING OF EXTERIOR DOOR AT ROOF ACCESS. ADD DOOR TO TRASH ROOM TO ACCESS TRASH FROM INTERIOR HALLWAY. VENT GROUND FLOOR EXISTING FURNACE FLUES TOWARDS THE REAR OF THE EXISTING 5 STORY TYPE IIIA MASONRY BUILDING CONTAINING 14 DWELLING UNITS, AS PER PLANS. NO CHANGE TO THE R2 OCCUPANCY CLASSIFICATION.","reportedCost":28000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101063258"},{"permit":"101078188","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-30","address":"2131 W FARRAGUT AVE","workDescription":"SELF-CERT 2019 CBRC; INTERIOR RENOVATION OF BASEMENT AT THE EXISTING 2-STORY FRAME, TYPE VB, SINGLE FAMILY RESIDENCE, GROUP R-5. THE WORK IS TO INCLUDE;- NEW PARTITIONS FOR BEDROOM SUITE WITH BATHROOM & STUDY AT BSMNT.ELECTRICAL, HVAC & PLUMBING MODIFICATIONS, PER PLANS.","reportedCost":25000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101078188"},{"permit":"101076910","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2026-01-09","address":"8135 W RASCHER AVE","workDescription":"SPR 2019 CBRC: INTERIOR RENOVATION AT FIRST FLOOR AND BSMT. EXISTING SERVICE AND PANEL 200AMP TO REMAIN. ELECTRICAL WORK AS PER PLANS . EXISTING FURNACE , AC UNIT TO REMAIN. SUPPLY AND RETURN TO REMAIN AT EXISTING SPLIT LEVEL BRICK SFR WITH BASEMENT. (OCCUPANCY R-5, CONSTRUCTION TYPE VA)","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076910"},{"permit":"B200455849","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-20","address":"11652 S HALE AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 2 SYSTEMS :   1 FLOOR FURNACE(REMOVING EXISTING FURNACE, COIL, AND CONDENSER INSTALLING A GOODMAN FURNACE 100000 BTU MOD# GRQ5801005CN)  1 OTHER COOLING EQUIPMENT(GOODMAN 2 1/2 TON CONDENSER WITH SCROLL  COMPRESSOR MOD# GSXTS403010) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  BASEMENT FURNACE ROOM.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200455849"},{"permit":"B200452448","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-30","address":"6759 S BELL AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 CENTRAL FURNACE(GOODMAN GR9S960604C IN BASEMENT) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  REPLACE FURNACE IN BASEMENT.","reportedCost":8000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200452448"},{"permit":"B200450935","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-02","address":"6203 S KILPATRICK AVE","workDescription":"DUCTWORK EXTENSION/RECONFIGURATION, GAS PIPING EXTENSION/RECONFIGURATION, ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS,  BRINGING FURNACE INSTALLATION UP TO CODE PER CITY.","reportedCost":6800,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200450935"},{"permit":"B200453844","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-30","address":"3242 W FOSTER AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 2 SYSTEMS :   1 ROOFTOP PACKAGED UNIT(NEW FURNACE TO REPLACE EXISTING RTU USING EXISTING DUCTWORK: GOODMAN GR9S801205DN)  1 OTHER COOLING EQUIPMENT(GOODMAN GLXS3BN4810) . ELECTRICAL WORK UNDER THIS PERMIT = YES . LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK,  1ST FLOOR STOREFRONT.","reportedCost":5000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200453844"},{"permit":"B200452389","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-21","address":"7150 S YATES BLVD","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 FLOOR FURNACE(TRANE X5 80000 BTU IN FURNACE ROOM (PHOTO INCLUDED).  AC WILL NOT BE CHANGED AT THIS TIME.) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  1ST FLOOR.","reportedCost":5000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200452389"},{"permit":"B200455047","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-08","address":"2118 W BERTEAU AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 CENTRAL FURNACE(CARRIER; TBD; IN UNIT UTILITY ROOM) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  UNIT 2118-1 IN UTILITY ROOM.","reportedCost":5000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200455047"},{"permit":"B200457527","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2026-01-29","address":"8007 S VINCENNES AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 CENTRAL FURNACE(GOODMAN GAS FURNACE 75) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS,  SECOND FLOOR APARTMENT.","reportedCost":4700,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200457527"}],"recordLimit":100}